- The Feasibility Study started as an EU project with the aim to determine requirements and conditions of the conversion, which was the base for Owners budget and further actions.
- A Hazid (risk analysis) was concluded by assistance and approval of Bureau Veritas.
- The main engine was converted to run on LNG/MDO
- Two LNG tanks, each with a capacity of 250 m3, was fitted on weather deck forward.
- A new LNG system including GVU unit installed in the engine room.
- Some existing equipment in the engine room were re-arranged.
- New Bunker stations and Vapour return stations were located on the weather deck in the vicinity of the existing manifold.
- Firefighting system, Hazardous zones and Stability have also been considered and determined.
The conversion after all preparations was concluded within a six weeks period.